Dual Power Automatic Transfer Switch PV Inverter Type Millisecond Switching 2P 110V 63A Circuit











Beskrivning
Feature: 1. Working Principle: When there is an abnormality in the normal power supply, the backup power supply immediately operates, ensuring the continuity, reliability, and safety of the power supply. 2. Auto Manual Modes: This transfer switch supports automatic and manual operation, millisecond switching, and widely used in various situations where continuous power outages are not allowed. 3. Stable Performance: This transfer switch has a compact structure, reliable transmission, rated current of 63A, coil voltage of 110VAC, suitable for emergency power supply system at 5060Hz. 4. Durable Materials: The changeover switch adopts PC flame retardant plastic shell, with good insulation, high temperature resistance, the silver alloy contact is aging resistance, has a long service life. 5. Applicable Fields: This dual power transfer switch has isolation anti interference, stable performance, and widely used in households, shopping malls, factories, laboratories, breeding farms, etc. Specification: Item Type: Dual Power Automatic Transfer Switch Product Model: NLQ31252P Material: Flame Retardant PC, Silver Alloy Switch Type: Secondary Distribution Rated Current: 63A Coil Voltage: 110V AC Insulation Voltage: AC690V AC Rated Voltage: AC400V AC Rated Frequency: 5060Hz Electrical Level: PC Isolation Type Rated Impulse Withstand Voltage: 8KV Control Circuit: Rated Control Voltage Us: AC110V 85percent Us110percent Us Auxiliary Circuit: 2 Relays, each with 2 sets of contacts capacity: AC110V50HZ le=5y Touch Time: <50ms Operation Switching Time: <50ms Return Time: <50ms Closing Time: <50ms. Package List: 1 x Dual Power Automatic Transfer Switch 1 x User Manual Note: 1. The maximum ambient temperature should not exceed 40 celsius , and the minimum should not be lower than ?5 celsius . The average temperature within 24 hours should not exceed 35 celsius . 2. The installation location should not be at an altitude exceeding 2000m. 3. When the highest temperature reaches 40 celsius , the relative humidity at the installation site should not exceed 50percent ; when the temperature is at the lowest ?5 celsius , the relative humidity is higher, for example: at a temperature of 25 celsius , the relative humidity is 90percent . Due to temperature changes, special measures should be taken to deal with occasional condensation on the surface of the product.Working Principle: When there is an abnormality in the normal power supply, the backup power supply immediately operates, ensuring the continuity, reliability, and safety of the power supply. Auto Manual Modes: This transfer switch supports automatic and manual operation, millisecond switching, and widely used in various situations where continuous power outages are not allowed. Stable Performance: This transfer switch has a compact structure, reliable transmission, rated current of 63A, coil voltage of 110VAC, suitable for emergency power supply system at 5060Hz. Durable Materials: The changeover switch adopts PC flame retardant plastic shell, with good insulation, high temperature resistance, the silver alloy contact is aging resistance, has a long service life. Applicable Fields: This dual power transfer switch has isolation anti interference, stable performance, and widely used in households, shopping malls, factories, laboratories, breeding farms, etc.





















